電力工程設(shè)計(jì)手冊(cè)pdf百度云(電力工程設(shè)計(jì)手冊(cè)pdf百度云盤)
大家好!今天讓創(chuàng)意嶺的小編來(lái)大家介紹下關(guān)于電力工程設(shè)計(jì)手冊(cè)pdf百度云的問(wèn)題,以下是小編對(duì)此問(wèn)題的歸納整理,讓我們一起來(lái)看看吧。
創(chuàng)意嶺作為行業(yè)內(nèi)優(yōu)秀企業(yè),服務(wù)客戶遍布全國(guó),相關(guān)業(yè)務(wù)請(qǐng)撥打175-8598-2043,或微信:1454722008
本文目錄:
一、求電氣專業(yè)畢業(yè)論文一篇?
相關(guān)數(shù)據(jù)直接在你們學(xué)校的圖書館里,或者圖書館的電子閱覽室里找你們學(xué)校有的數(shù)據(jù)庫(kù),就可以了,最好是找核心期刊,普刊的話作用比較小,直接找論文參考也可以,但是要防止雷同比率哦!
論文要想寫好,寫出色,先確定題目,一定要和老師商量,因?yàn)槟阆矚g的并不一定是老師喜歡的,然后把要寫作的論點(diǎn)確定了,然后再找資料選擇論據(jù)證明你的論點(diǎn)是正確的。最后給老師列個(gè)大綱看一下確定框架,同意了在開(kāi)始著手寫。
你的電氣自動(dòng)化專業(yè)論文準(zhǔn)備往什么方向?qū)?,選題老師審核通過(guò)了沒(méi),有沒(méi)有列個(gè)大綱讓老師看一下寫作方向?
老師有沒(méi)有和你說(shuō)論文往哪個(gè)方向?qū)懕容^好?寫論文之前,一定要寫個(gè)大綱,這樣老師,好確定了框架,避免以后論文修改過(guò)程中出現(xiàn)大改的情況??!
學(xué)校的格式要求、寫作規(guī)范要注意,否則很可能發(fā)回來(lái)重新改,你要還有什么不明白或不懂可以問(wèn)我,希望你能夠順利畢業(yè),邁向新的人生。
擬寫論文寫作提綱,首先必須了解論文寫作提綱的構(gòu)成。
一份完整、正規(guī)的論文寫作提綱,應(yīng)由以下項(xiàng)目構(gòu)成:
(1)標(biāo)題
標(biāo)題是一篇文章的名稱,也是文章內(nèi)容的標(biāo)示性語(yǔ)句。論文作者為論文擬定標(biāo)題,一般
可以著眼于兩個(gè)方面,也就是說(shuō)可以從兩個(gè)角度去考慮,這樣,論文的標(biāo)題也就相應(yīng)地形成了兩種類型:
一種是揭示課題的標(biāo)題。這類標(biāo)題所反映的只是文章所要證明的問(wèn)題,而不涉及作者對(duì)問(wèn)題的看法。論文標(biāo)題多為揭示課題的標(biāo)題。
另一種是揭示論點(diǎn)的標(biāo)題。這類標(biāo)題直接反映作者對(duì)問(wèn)題的看法,或者說(shuō)標(biāo)題就是對(duì)文章的內(nèi)容要點(diǎn)的概括。揭示論點(diǎn)的標(biāo)題雖然不如揭示課題的標(biāo)題用得那么普遍,但也應(yīng)當(dāng)算是一種比較常見(jiàn)的標(biāo)題形式。
除了上面兩類單行標(biāo)題之外,學(xué)術(shù)論文還經(jīng)常使用雙行標(biāo)題。有的雙行標(biāo)題中的正標(biāo)題標(biāo)明論點(diǎn)或與論點(diǎn)有關(guān),副標(biāo)題著重揭示課題或與課題有關(guān)。
作者在編制寫作提綱時(shí)所擬定的標(biāo)題,既可能就此便被確定下來(lái),最后成為文章的標(biāo)題,也就是說(shuō),寫作提綱中的標(biāo)題同論文定稿后的標(biāo)題完全相同;也可能要經(jīng)過(guò)加工、潤(rùn)色,才能用做文章的標(biāo)題,提綱上的標(biāo)題同論文定稿后的標(biāo)題有所不同;甚或在起草、修改文章時(shí),隨著認(rèn)識(shí)的深化和文章內(nèi)容的調(diào)整,作者感到標(biāo)題也需要重新考慮,最初擬定的標(biāo)題同最終確定下來(lái)的標(biāo)題完全不同。
(2)觀點(diǎn)句
觀點(diǎn)句也叫論點(diǎn)句或主題句,簡(jiǎn)單地說(shuō),所謂的觀點(diǎn)句就是概括全篇文章的基本觀點(diǎn)
的語(yǔ)句。
把文章的基本觀點(diǎn)寫在提綱中,落實(shí)到書面上,不僅有利于觀點(diǎn)的進(jìn)—步梳理和明確,而且能夠有效地防止“寫跑題”,因?yàn)橛^點(diǎn)句會(huì)時(shí)時(shí)提醒、限制作者,使作者牢記文章的中心之所在。
觀點(diǎn)句不是論文提綱的必備項(xiàng)目,但內(nèi)容比較復(fù)雜的論文一般應(yīng)當(dāng)寫出觀點(diǎn)句。
(3)內(nèi)容綱要
內(nèi)容綱要是論文寫作提綱的主體部分。在這—部分中,要以分條列項(xiàng)的形式把論文正文
部分的構(gòu)成狀況如實(shí)地反映出來(lái)。
內(nèi)容綱要常見(jiàn)的寫作形式為:
一、大的部分或大的層次的論點(diǎn)
(一)段的論點(diǎn)
…………
1.段內(nèi)層次的意思
…………
(1)材料
…………
二、同上
三、同上
…………
寫作提綱中的內(nèi)容綱要就是一篇文章的結(jié)構(gòu)關(guān)系圖,編寫內(nèi)容綱要,絕非簡(jiǎn)單地羅列各級(jí)論點(diǎn)與各種材料,而是要設(shè)置出一個(gè)能夠包容全部觀點(diǎn)及主要材料的邏輯框架,并使觀點(diǎn)與材料在這個(gè)框架中都能得到一個(gè)最為恰當(dāng)?shù)奈恢谩?nèi)容綱要大都從大的部分寫起,即先寫出大的部分或大的層次的論點(diǎn),然后是該部分或該層次內(nèi)的中項(xiàng)目,最后是中項(xiàng)目中的各個(gè)小項(xiàng)目。而在依照內(nèi)容綱要起草論文時(shí),則要從小的項(xiàng)目著筆,從一個(gè)部分的小項(xiàng)目再到另一個(gè)部分的小項(xiàng)目,漸次完成全文。
內(nèi)容綱要是由各級(jí)項(xiàng)目構(gòu)成的,項(xiàng)目的寫法有兩種:一種是標(biāo)題式寫法,即以標(biāo)題的形式把該部分的內(nèi)容概括出來(lái);一種是句子式寫法,即以語(yǔ)意完整的句子形式把該部分的內(nèi)容概括出來(lái)。兩種寫種各有利弊,前者簡(jiǎn)潔,但別人不易看懂,甚至過(guò)一段時(shí)間之后,作者本人也會(huì)有不解之處;后者具體,但中心不夠突出,不便于觸發(fā)思考。擬定提綱究竟采用哪種項(xiàng)目寫法,要根據(jù)實(shí)際情況(如論文寫作時(shí)間的長(zhǎng)短、論文內(nèi)容的繁簡(jiǎn)等等)和個(gè)人習(xí)慣而定。
寫作提綱的編制,標(biāo)志著起草論文前的準(zhǔn)備工作的結(jié)束,接著就可以進(jìn)入下一個(gè)階段——論文的起草階段了。
畢業(yè)論文怎么寫?首先要弄明白作格式,其次是選題,再次是確定立意,最后是材料搜集和寫作。
二、畢業(yè)論文選題
你可以到百度上搜一搜與你相關(guān)的學(xué)科論文題目,你會(huì)從中獲得很大啟迪。
三、畢業(yè)論文立意
你可以在比較中找到別人還沒(méi)說(shuō)到或說(shuō)得不全面的地方作為自己的立意方向。
四、材料搜集
就是搜集能證明自己立意的素材??梢酝ㄟ^(guò)圖書搜集,也可以通過(guò)百度查找。
五、畢業(yè)論文寫作
要注意格式正確,用語(yǔ)規(guī)范,條理清晰,論證充分。廣義來(lái)說(shuō),凡屬論述科學(xué)技術(shù)內(nèi)容的作品,都稱作科學(xué)著述,如原始論著、簡(jiǎn)報(bào)、綜合報(bào)告、進(jìn)展報(bào)告、文獻(xiàn)綜述、述評(píng)、專著、匯編、教科書和科普讀物等。但其中只有原始論著及其簡(jiǎn)報(bào)是原始的、主要的、第一性的、涉及到創(chuàng)造發(fā)明等知識(shí)產(chǎn)權(quán)的。其它的當(dāng)然也很重要,但都是加工的、發(fā)展的、為特定
應(yīng)用目的和對(duì)象而撰寫的。下面僅就原始論著的撰寫談一些體會(huì),同時(shí)對(duì)如何做好學(xué)術(shù)報(bào)告也談一些經(jīng)驗(yàn)。在討論原始論著寫作時(shí)也不準(zhǔn)備談?dòng)嘘P(guān)稿件撰寫的各種規(guī)定及細(xì)則。我主要談的是寫作中容易發(fā)生的問(wèn)題和經(jīng)驗(yàn),是寫作道德和書寫內(nèi)容的規(guī)范問(wèn)題。
二、電氣工程及其自動(dòng)化論文怎么寫
確定主題,找相關(guān)的論文做模板,照著模板的格式和框架結(jié)構(gòu)填寫自己的內(nèi)容,這里有一個(gè)范本:
電氣工程及其自動(dòng)化論文范本2010-04-22 14:22論文主要內(nèi)容包括
1.摘要
2.英文翻譯
3.原始資料
4.計(jì)算書
5.說(shuō)明書
6.參考文獻(xiàn)
7.圖紙
簡(jiǎn)單區(qū)域電力網(wǎng)絡(luò)系統(tǒng)的一次或二次設(shè)計(jì)畢業(yè)論文
目錄:
第一章. 設(shè)計(jì)依據(jù)
第二章. 原始資料
第三章 接入系統(tǒng)設(shè)計(jì)
第四章 地方供電系統(tǒng)設(shè)計(jì)
第五章 主變選擇(包括抽頭選擇或調(diào)整方式設(shè)計(jì))
第六章 主接線設(shè)計(jì)(包括所用電設(shè)計(jì))
第七章 短路電流計(jì)算
第八章 設(shè)備選擇
第九章 繼電保護(hù)配置
[正文]:
第一章.設(shè)計(jì)依據(jù)
根據(jù)××大學(xué)電氣工程及自動(dòng)化專業(yè)畢業(yè)任務(wù)書
第二章.原始資料
為了滿足工農(nóng)業(yè)生產(chǎn)發(fā)展的需要,經(jīng)上級(jí)批準(zhǔn),決定新建110KV鹽北變電所。
一. 設(shè)計(jì)資料
(一) 新建的鹽北變電所各電壓級(jí)負(fù)荷數(shù)據(jù),回路,同時(shí)率等見(jiàn)表3。
鹽北變電所每年負(fù)荷增長(zhǎng)率5%,需考慮五年發(fā)展規(guī)劃
變電所總負(fù)荷 s110=K 1(s35+s10)(1+5%)
(二) 新建的鹽北變電所,受電方案有兩種:(1)從110K
鹽城東郊變受電距離30KM(本課題做);(2)從110KV灌南變受電距離35KM(本課題不做),電力系統(tǒng)接線圖見(jiàn)圖1
(三) 電力系統(tǒng),各廠、所、輸電線等主設(shè)備技術(shù)參數(shù)見(jiàn)表1、2、3、4、5。
(四) 其它原始資料:
所址:地形地勢(shì)平坦、土址電阻率為1.5×10 歐•厘米,所址高于百年一遇最高洪水位。所址所在地氣候,平均氣溫15℃,最高氣溫35℃,最低氣溫-15℃。
交通:緊靠國(guó)家二級(jí)公路,進(jìn)所公路0.4公里。
水源:變電所附近有河流供方方便,水量充足。
二.設(shè)計(jì)內(nèi)容
(一) 接入系統(tǒng)設(shè)計(jì):
確定接入系統(tǒng)輸電線路回路數(shù)及導(dǎo)線截面。
(二) 地區(qū)供電系統(tǒng)設(shè)計(jì):
根據(jù)地區(qū)負(fù)荷性質(zhì)及供電距離,確定供電線路數(shù)及導(dǎo)線截面。
(三) 通過(guò)技術(shù)、經(jīng)濟(jì)比較,確定變電所主變壓器臺(tái)數(shù)及容量、型號(hào)、規(guī)格。
(四) 通過(guò)電壓計(jì)算、選擇主變分接頭或調(diào)壓方式。
(五) 根據(jù)所確定的主變方案和進(jìn)出線回路數(shù),通過(guò)技術(shù)分析、論證,確定待建變電所的主接線。
(六) 確定待建變電所的所用電方案(所用變壓器臺(tái)數(shù)、型號(hào)、容量和自用電接線型式,所用電負(fù)荷按0.1%變電所容量計(jì))。
(七) 電氣設(shè)備選擇
1. 為選擇電器設(shè)備和繼電器保護(hù)整定需要,計(jì)算三相短路電流。
2. 選擇變電所電氣一次設(shè)備(斷路器、隔離開(kāi)關(guān)、PT、CT、母線、避雷器及中性點(diǎn)接地設(shè)備)。
(八) 繼電保護(hù)
根據(jù)繼電保護(hù)要求,確定變電所各元件繼電保護(hù)配置。
......
[摘要]:
本設(shè)計(jì)說(shuō)明書是根據(jù)畢業(yè)設(shè)計(jì)任務(wù)書的要求,結(jié)合“電氣設(shè)備”、“電力系統(tǒng)暫態(tài)分析”、“電力系統(tǒng)穩(wěn)態(tài)分析”、“繼電保護(hù)”、“電氣工程專業(yè)畢業(yè)設(shè)計(jì)指南”等有關(guān)書籍而制定的,是我三年大學(xué)學(xué)習(xí)的總結(jié)。
三年中,在授課老師的指導(dǎo)下,學(xué)到了很多的知識(shí),對(duì)我的學(xué)習(xí)生涯和社會(huì)實(shí)踐生活有很大的促進(jìn)使我不斷的挑戰(zhàn)自我、充實(shí)自己,不僅思想上有了大的收獲,知識(shí)上也有質(zhì)的突破。同時(shí)也注重于將所學(xué)習(xí)的知識(shí)運(yùn)用與實(shí)際工作中 ,增強(qiáng)了處理分析問(wèn)題的能力。
這次設(shè)計(jì)的新建110KV變電所本著為國(guó)民經(jīng)濟(jì)各個(gè)部門提供充足的電能,最大限度地滿足用戶的用電需要,保證供電的可靠性,保證良好的電能質(zhì)量,提高電力系統(tǒng)運(yùn)行經(jīng)濟(jì)性的原則進(jìn)行設(shè)計(jì)。是針對(duì)接入系統(tǒng)設(shè)計(jì):確定接入系統(tǒng)輸電線路回路數(shù)及導(dǎo)線截面。地區(qū)供電系統(tǒng)設(shè)計(jì):根據(jù)地區(qū)負(fù)荷性質(zhì)及供電距離,確定供電線路數(shù)及導(dǎo)線截面。通過(guò)技術(shù)、經(jīng)濟(jì)比較,確定變電所主變壓器臺(tái)數(shù)及容量、型號(hào)、規(guī)格。通過(guò)電壓計(jì)算、選擇主變分接頭或調(diào)壓方式。根據(jù)所確定的主變方案和進(jìn)出線回路數(shù),通過(guò)技術(shù)分析、論證,確定待建變電所的主接線。確定待建變電所的所用電方案(所用變壓器臺(tái)數(shù)、型號(hào)、容量和自用電接線型式,所用電負(fù)荷按0.1%變電所容量計(jì))。電氣設(shè)備選擇:為選擇電器設(shè)備和繼電器保護(hù)整定需要,計(jì)算三相短路電流。選擇變電所電氣一次設(shè)備(斷路器、隔離開(kāi)關(guān)、PT、CT、母線、避雷器及中性點(diǎn)接地設(shè)備)。繼電保護(hù)根據(jù)繼電保護(hù)要求,確定變電所各元件繼電保護(hù)配置。
Prolegomenon
This design explains is basis of graduate design assignment book, combine bear on book that《electric equipment》、《electric system steady condition analyzing》、《relay safeguard》、《electric engineering specialty enchiridion of graduate design》,this is my summarize of three years in university .
In three years, depend on teachers go to supervise, acquire many knowledge, promote me that learning 、work and live, ceaseless challenge me and enrich me, not only my inwardly harvest and that go up knowledge. Likewise pay attention to in the work.
This time design of 110KV substation tenet that in order to afford ample electricity of country every department, ensure power supply, ensure power supply finer quality, and promote electric system economy. This time design of running system design (fix on transmit electricity circuitry loops of running system and section of circuitry); fix on number that mains transformer of substation, and capability 、type、specification; compute voltage、choose tap place, compare economy and technology; fix on power supply blue print of substation; compute electrical current of three route short circuit ; choose electric equipment (breaker、seclusion switch、PT、CT、generatrix、arrester、grounding equipment )and relay safeguard , fix on relay safeguard configure of substation.
[參考文獻(xiàn)]:
1.《發(fā)電廠電氣部分課程設(shè)計(jì)參考資料》 水力電力出版社
2.《電力系統(tǒng)設(shè)計(jì)設(shè)備參考資料》 河海大學(xué)出版社
3.《電力系統(tǒng)穩(wěn)態(tài)分析》 水力電力出版社
4.《電力系統(tǒng)暫態(tài)分析》 水力電力出版社
5.《電力工程設(shè)計(jì)手冊(cè)》 水力電力西北電力設(shè)計(jì)院
6.《發(fā)電廠電氣部分》 水力電力出版社
7.《電力系統(tǒng)繼電保護(hù)原理》 水力電力出版社
8.《電力系統(tǒng)課程設(shè)計(jì)及畢業(yè)參考資料》 中國(guó)電力出版社
你這個(gè)題目太寬泛了,你在網(wǎng)上輸入電氣工程概論,查找相關(guān)資料,再然后按照自己的思路合理組織和取舍材料就行了.實(shí)在是對(duì)不起,他人可不能夠代替你寫這么多的文字呀!只能夠告訴你一個(gè)大概了,關(guān)鍵還得靠自己寫了
三、正序電流的大小與變壓器的數(shù)量
正序電流的大小與變壓器的數(shù)量
首先選擇變壓器的額定電壓。高壓側(cè)電壓與所接入電網(wǎng)電壓相等,低壓側(cè)電壓比低壓側(cè)電網(wǎng)的電壓高10%或5%(取決變壓器電壓等級(jí)和阻抗電壓大?。?;額定容量選擇。
計(jì)算變壓器所帶負(fù)荷的大?。ㄒ蠼y(tǒng)計(jì)最大綜合負(fù)荷,將有功負(fù)荷kW值換算成視在功率kVA),如果是兩臺(tái)變壓器,那么每臺(tái)變壓器的容量可按照最大綜合負(fù)荷的70%選擇,一臺(tái)變壓器要按總負(fù)荷考慮,并留有適當(dāng)?shù)脑6?。其它名牌參?shù)可結(jié)合變壓器產(chǎn)品適當(dāng)考慮。
例如:選擇35/10kV變壓器。假定最大負(fù)荷為3500kW,功率因數(shù)為0.8,選兩臺(tái)變壓器,容量S=0.7×3500/0.8=3062kVA,可選擇3150kVA的變壓器,電壓比為35kV/10.5kV。再?gòu)漠a(chǎn)品目錄中選擇型號(hào)。
一、變壓器容量計(jì)算公式
1、計(jì)算負(fù)載的每相最大功率
將A相、B相、C相每相負(fù)載功率獨(dú)立相加,如A相負(fù)載總功率10KW,B相負(fù)載總功率9KW,C相負(fù)載總功率11KW,取最大值11KW。(注:?jiǎn)蜗嗝颗_(tái)設(shè)備的功率按照銘牌上面的最大值計(jì)算,三相設(shè)備功率除以3,等于這臺(tái)設(shè)備的每相功率。)
例如:C相負(fù)載總功率=電腦300W×10臺(tái))+(空調(diào)2KW×4臺(tái))=11KW
2、計(jì)算三相總功率
11KW×3相=33KW(變壓器三相總功率)
三相總功率/0.8,這是最重要的步驟,目前市場(chǎng)上銷售的變壓器90%以上功率因素只有0.8,所以需要除以0.8的功率因素。
33KW/0.8=41.25KW(變壓器總功率)
變壓器總功率/0.85,根據(jù)《電力工程設(shè)計(jì)手冊(cè)》,變壓器容量應(yīng)根據(jù)計(jì)算負(fù)荷選擇,對(duì)平穩(wěn)負(fù)荷供電的單臺(tái)變壓器,負(fù)荷率一般取85%左右。
41.25KW/0.85=48.529KW(需要購(gòu)買的變壓器功率),那么在購(gòu)買時(shí)選擇50KVA的變壓器就可以了。

二、關(guān)于變壓器容量計(jì)算的一些問(wèn)題
1、變壓器的額定容量,應(yīng)該是變壓器在規(guī)定的使用條件下,能夠保證變壓器正常運(yùn)行的最大載荷視在功率;
2、這個(gè)視在功率就是變壓器的輸出功率,也是變壓器能帶最大負(fù)載的視在功率;
3、變壓器額定運(yùn)行時(shí),變壓器的輸出視在功率等于額定容量;
4、變壓器額定運(yùn)行時(shí),變壓器的輸入視在功率大于額定容量;
5、由于變壓器的效率很高,一般認(rèn)為變壓器額定運(yùn)行時(shí),變壓器的輸入視在功率等于額定容量,由此進(jìn)行的運(yùn)算及結(jié)果也是基本準(zhǔn)確的;
6、所以在使用變壓器時(shí),你只要觀察變壓器輸出的電流、電壓、功率因數(shù)及其視在功率等于或小于額定容量就是安全的(使用條件滿足時(shí));
7、有人認(rèn)為變壓器有損耗,必須在額定容量90%以下運(yùn)行是錯(cuò)誤的!
8、變壓器在設(shè)計(jì)選用容量時(shí),根據(jù)計(jì)算負(fù)荷要乘以安全系數(shù)是對(duì)的。
可以看到變壓器容量計(jì)算其實(shí)不難。主要是要注意變壓器容量計(jì)算的一些問(wèn)題。
變壓器額定電流計(jì)算
額定電流是指用電設(shè)備在額定電壓下,按照額定功率運(yùn)行時(shí)的電流。也可定義為電氣設(shè)備在額定環(huán)境條件(環(huán)境溫度、日照、海拔、安裝條件等)下可以長(zhǎng)期連續(xù)工作的電流。用電器正常工作時(shí)的電流不應(yīng)超過(guò)它的額定電流。
額定電流是由繞組的額定容量除以該繞組的額定電壓及相應(yīng)的系數(shù)(單相為1,三相為√3)而算得的流經(jīng)繞組線端的電流。因此,變壓器的額定電流就是各繞組的額定電流,是指線電流。但是,組成三相組的單相變壓器,如繞組為三角形聯(lián)結(jié),繞組的額定電流則以線電流為分子,以√3為分母來(lái)表示,例如線電流為500A,則繞組的額定電流為(500/√3)A。
變壓器在額定容量下運(yùn)行時(shí),繞組的電流為額定電流。參照國(guó)家標(biāo)準(zhǔn)GB/T15164—1994《油浸式電力變壓器負(fù)載導(dǎo)則》,變壓器可以過(guò)載運(yùn)行,三相的額定容量不超過(guò)100 MVA(單相不超過(guò)33.3 MVA)時(shí),可承受負(fù)載率(負(fù)載電流/額定電流)不大于1.5的偶發(fā)性過(guò)載,容量更大時(shí)可承受負(fù)載率不超過(guò)1.3的偶發(fā)性過(guò)載。
套管也應(yīng)有相應(yīng)的過(guò)載能力,繞組熱點(diǎn)溫度和頂層油溫度分別不能超過(guò)140℃和105℃。
額定電流選擇
一、普通電抗器的額定電流選擇
(1)電抗器幾乎沒(méi)有過(guò)負(fù)荷能力,所以主變壓器或出線回路的電抗器,應(yīng)按回路最大工作電流選擇,而不能用正常持續(xù)工作電流選擇。
(2)對(duì)于發(fā)電廠母線分段回路的電抗器,應(yīng)根據(jù)母線上事故切斷最大一臺(tái)發(fā)電機(jī)時(shí),可能通過(guò)電抗樸的電流選擇。一般取該臺(tái)發(fā)電機(jī)額定電流的50%~80%。
(3)變電所母線分段回路的電抗憎應(yīng)滿足用戶的一級(jí)負(fù)荷和大部分二級(jí)負(fù)荷的要求。
二、分裂電抗器的額定電流選擇
(1)當(dāng)由于發(fā)電廠的發(fā)電機(jī)或主變壓器回路時(shí),一般按發(fā)電機(jī)或主變壓器額定電流的70%選擇。
(2)當(dāng)用于變電所主變壓器回路時(shí),應(yīng)按負(fù)荷電流大的中通過(guò)的最大負(fù)荷電流選擇。當(dāng)無(wú)負(fù)荷資料時(shí),一般按主變壓器額定電流的70%選擇。
變壓器額定電流怎么計(jì)算
變壓器額定電流表


變壓器額定電流計(jì)算
變壓器額定電流 I1N/I2N,單位為A、kA。是變壓器正常運(yùn)行時(shí)所能承擔(dān)的電流,在三相變壓器中均代表線電流。
變壓器額定電流計(jì)算公式 對(duì)單相變壓器:I1N = SN/ U1N I2N = SN / U2N 對(duì)三相變壓器:I1N=SN/[sqrt(3)U1N] I2N=SN/[sqrt(3)U2N]
U1N為正常運(yùn)行時(shí)一次側(cè)應(yīng)加的電壓。U2N為一次側(cè)加額定電壓、二次側(cè)處于空載時(shí)的電壓。單位為V。相變壓器中,額定電壓指的是線電壓。
SN為變壓器額定容量,單位為VA、kVA、MVA,N為變壓器的視在功率。通常把變壓器一、二次側(cè)的額定容量設(shè)計(jì)為 。
I1N為正常運(yùn)行時(shí)一次側(cè)變壓器額定電流。I2N為一次側(cè)變壓器額定電流。單位為A。
250KVA有效使用功率等于百分之八十,250KVA等于200KW 變壓器二次側(cè)電流=變壓器額定容量*1.44。
例如:100KVA變壓器二次側(cè)電流
I=100*1.44=144(A)
各種容量變壓器高低壓側(cè)額定電流的數(shù)據(jù)(包括20、30、50、80、100、160、200、250、315、400KVA等)
變壓器容量20、30、 50、 80、 100、 160、 200、 250、 315、 400KVA
高壓側(cè)電流1.15、1.73、2.88、4.62、5.77、 9.23、11.2、14.43、18.2、 22.4
低壓側(cè)電流28.9、43.2、 72、 115.2、144、230.4、288、 360、453.6、 576 已知變壓器容量,求其各電壓等級(jí)側(cè)額定電流。
口訣a :容量除以電壓值,其商乘六除以十。
說(shuō)明:適用于任何電壓等級(jí)。
在日常工作中,有些電工只涉及一兩種電壓等級(jí)的變壓器額定電流的計(jì)算。將 以上口訣簡(jiǎn)化,則可推導(dǎo)出計(jì)算各電壓等級(jí)側(cè)額定電流的口訣:容量系數(shù)相乘求。已知變壓器容量,速算其一、二次保護(hù)熔斷體(俗稱保險(xiǎn)絲)的電流值。
口訣b :
配變高壓熔斷體,容量電壓相比求。
配變低壓熔斷體,容量乘9除以5。
說(shuō)明:正確選用熔斷體對(duì)變壓器的安全運(yùn)行關(guān)系極大。當(dāng)僅用熔斷器作變壓器高、低壓側(cè)保護(hù)時(shí),熔體的正確選用更為重要。這是電工經(jīng)常碰到和要解決的問(wèn)題。
四、什么是正母線和付母線,它們各在電路中起什么作用?
正副母線是一種習(xí)慣叫法,傳統(tǒng)的叫法為雙母線帶旁路,兩段工作母線本無(wú)正副之分,只是相對(duì)而言,有的地方把長(zhǎng)期或經(jīng)常與饋線斷路器鏈接的母線稱為正母線,將不經(jīng)常與饋線斷路器鏈接的母線稱為副母線,旁路母線必須與旁路開(kāi)關(guān)(斷路器)配合使用,它的功能是當(dāng)工作母線上任一臺(tái)斷路器需要檢修而退出運(yùn)行時(shí),由旁路開(kāi)關(guān)(斷路器)通過(guò)旁路母線來(lái)代替退出運(yùn)行的斷路器,以保持系統(tǒng)的供電方式不變,這種接線適用于對(duì)供電的連續(xù)性要求很高的變電所,系統(tǒng)接線詳圖請(qǐng)見(jiàn)“電力工程設(shè)計(jì)手冊(cè)”第一冊(cè),第17頁(yè) 圖1-23 220KV大型變電所主接線
以上就是關(guān)于電力工程設(shè)計(jì)手冊(cè)pdf百度云相關(guān)問(wèn)題的回答。希望能幫到你,如有更多相關(guān)問(wèn)題,您也可以聯(lián)系我們的客服進(jìn)行咨詢,客服也會(huì)為您講解更多精彩的知識(shí)和內(nèi)容。
推薦閱讀:
惠州電力勘察設(shè)計(jì)院(惠州電力勘察設(shè)計(jì)院有限公司是國(guó)企嗎)
工業(yè)廠房電力負(fù)荷設(shè)計(jì)標(biāo)準(zhǔn)(工業(yè)廠房電力負(fù)荷設(shè)計(jì)標(biāo)準(zhǔn)最新)
豐澤抖音代運(yùn)營(yíng)方案(抖音代運(yùn)營(yíng)具體方案)
暢銷小說(shuō)排行榜前十名(2022年暢銷書排行榜前十名)
猜你喜歡
中國(guó)前50游戲公司(中國(guó)前50游戲公司2020)
給排水系統(tǒng)簡(jiǎn)稱(給排水系統(tǒng)介紹)
廣場(chǎng)優(yōu)秀案例(廣場(chǎng)優(yōu)秀案例分享)
電子產(chǎn)品logo設(shè)計(jì)圖片(電子產(chǎn)品logo設(shè)計(jì)圖片素材)
空調(diào)排風(fēng)項(xiàng)目在哪個(gè)網(wǎng)站查詢(空調(diào)排風(fēng)項(xiàng)目在哪個(gè)網(wǎng)站查詢信息)